Thorlabs Inc.
Visit the Polarization Dependent Balanced Detector page for pricing and availability information

Polarization Dependent Balanced Detector

Hide Overview

OVERVIEW

Item #INT-POL-1300
Optical Parameters
Wavelength Range*1270 - 1350 nm
Fiber TypeCorning SMF28
Optical ConnectorsFC/APC
Extinction Ratio (PBS)22 dB
Max. Input Power 1300 nm 20 mW
Electrical Parameter
Detector Material/TypeInGaAs / PIN
Detector Wavelength Range800 - 1700 nm
Typical Max. Responsivity1.0 A/W
Output Bandwidth RF OutputDC - 15 MHz
Output Bandwidth Monitor OutputDC - 5 MHz
Transimpedance Gain50 x 10³ V/A
Conversion Gain Monitor Outputs5 V/mW
Saturation Power80 µW @ 1300 nm
Electrical Output /ImpedanceSMA, 50 Ω
DC Offset±10 mV
Power Supply ±12 V, 200 mA
All accuracy data is valid at 23 ± 5 °C and 45% Humidity

*The limitation of the operating wavelength range of the INT-POL-1300 module is determined by the bandwidth of the two polarization beamsplitters used. The central wavelength of these beamsplitters is 1310nm, with a +/-40 nm operating bandwidth. (See the manual supplied for more information). Other wavelength ranges may be available, please contact techsupport@thorlabs.com for details.

Features

  • Compact Design
  • Integrated Signal Detection with Active Aliasing Filter
  • Fast Monitor Outputs for External Polarization Adjustment
  • Excellent Common Mode Rejection
  • Matched Lengths of S and P Paths

The INT-POL-1300 is an integrated pair of balanced detectors that are used to analyze the S and P States of Polarization (SOP) of two input signals independently. This compact system is designed for polarization sensitive optical coherence tomographyy (OCT) applications, but it can be used in any application where the difference between two signals has to be analyzed with high sensitivity.

Functionality of Balanced Receivers

The S and P polarization states of the input are split using a polarization beamsplitters (PBS). The split inputs are directed into two balanced detectors, one for each SOP. These balanced photodetectors operate in the same manner as our PDB400 Series of OCT Balanced Detectors, they subtract the two optical input signals from each other resulting in the cancellation of common mode noise. This allows small changes on the signal path to be extracted from the interfering noise floor for each SOP.

Noise Reduction

These receivers are comprised of two balanced photodetectors and an ultra-low-noise, high-speed transimpedance amplifier. The advanced design allows an improved matching of the two balanced photodetectors to achieve an excellent common mode rejection, leading to better noise reduction. Futhermore the balanced detectors have active low-pass filters to prevent aliasing effects and to suppress out of band noise effectively.

Connectors

Optical signals are coupled to the photodiodes via two FC/APC input connectors. The unit has 6 electrical SMA output connectors 3 per polarization state, i.e. 3 for the S and 3 for the P polarisation state. One of these 3 outputs provides the balanced signal and the other two are the power monitor outputs. The monitor outputs enable the control of the input power levels for each detector separately and can be used to adjust the input SOPs for each channel independently. The device is powered via an ±12 V DC input connector.

Packaging and Power Supply

The unit is housed in a rugged, shielded aluminum enclosure. The unit is powered from a ±12 Volts DC power supply which is included.

Thorlabs also offers Fiber-Based Interferometers, which feature an integrated balanced detector.

Hide Pin Diagrams

PIN DIAGRAMS

RF Output

BNC Female

BNC Female

Maximum Voltage is ±3.6 V for Hi-Z & ±1.8 V into 50 Ω loads.

Monitor (+/-)

BNC Female

BNC Female

Maximum Voltage is +10 V for Hi-Z & +1.5 V into 50 Ω loads.

Hide Part Numbers
Part Number
Description
Price
Availability
INT-POL-1300
Polarization-Dependent Balanced Detector
$2,400.00
Today